Tender For supply of srphc82278027-crt- p pulse generator for delivery of cardiacresynchronizationtherapy. system should include a current generation crt pulse generator compatible with bipolar steroid-eluting atrial and ventricular leads and a biploar left ventricular lead (coronary sinus ). should provide independently programmable right and left ventricular pulse outputs and interventricular delay ( with the choices of right ventricular alone, leftventricular alone or biventricular pacing as well as the choice of which ventricle is to bepaced first with optimization of delay for pacing of other ventricle ). should have features like negative av hysteresis and triggered modes for continuous delivery of crt. should have advanced features for detection and management and prevention of atrialtachycardias and atrial fibrillation as well as detailed data storage of all arrhythmias and therapy as well as trends over time. should have features for management of atrial fibrillation including mode switch, ventricular rate management etc., pulse generator should be suitable for use with either an endocardial lv lead or an epimyocardial lead for lv stimulation. lv leads should have optimal features for introduction, positioning and fixation and documented low displacement rates. safety and efficacy of the system should be well documented. unit: number. ]
Tender For supply of srphc82278027-crt- p pulse generator for delivery of cardiacresynchronizationtherapy. system should include a current generation crt pulse generator compatible with bipolar steroid-eluting atrial and ventricular leads and a biploar left ventricular lead (coronary sinus ). should provide independently programmable right and left ventricular pulse outputs and interventricular delay ( with the choices of right ventricular alone, leftventricular alone or biventricular pacing as well as the choice of which ventricle is to bepaced first with optimization of delay for pacing of other ventricle ). should have features like negative av hysteresis and triggered modes for continuous delivery of crt. should have advanced features for detection and management and prevention of atrialtachycardias and atrial fibrillation as well as detailed data storage of all arrhythmias and therapy as well as trends over time. should have features for management of atrial fibrillation including mode switch, ventricular rate management etc., pulse generator should be suitable for use with either an endocardial lv lead or an epimyocardial lead for lv stimulation. lv leads should have optimal features for introduction, positioning and fixation and documented low displacement rates. safety and efficacy of the system should be well documented. unit: number. ]
Tender For e-05 (26-27) medical equipment for emergency area and opd area on turnkey basis at new general hospital building adult and paediatric ventilator, transport ventilaotr, anaesthsia workstation, multipara monitor, ecg, defibrilator, ot tabel, usg, mobile dr x-ray machine, fixed dr x ray system, electrocautery with vessel sealer, nerve stimulator, fluid warmer, patient warmer, abg, crash cart, icu bed, ward bed, medicine trolly, bedside locker/table, overbed tabels, wheel chair, stretcher, patient examination tables, suction machine, adult & paeds ambu bag, nebulizer, syringe pump, infusion pump, bp apratus - mercury less, c pap machine, ent opd workstation, video laryngoscope, opthalm trail lens set, indirect opthlmoscope, direct opthlmoscope, perimeter, slit lamp, ophthalmic refraction unit, autoref-kertometer, a scan, turnkey work(electrical, civil, plumbing) required for installation